Arc Flash Study

12,500
   Chennai, Tamil Nadu
12,500
Wish List  Add to wishlist    |     Write a review    |     Report

Dear User,


Thanks for notify us about Ad ID : 617787.


Our team will review and take appropriate action in next 24 hours. We look forward for your continuous support.


Thanks & Regards
Zamroo Team

×
SUMMARYPosted: 3 months ago

Type

DESCRIPTION

Arc Flash studies – An arc flash is a phenomenon where a flash-over of electric current leaves its intended path and travels through the air from one conductor to another or the ground. The results are often violent and when a human is close to the arc flash, serious injury and even death can occur. Arc flash can be caused by many things including Dust, Dropping tools, Accidental touching, Condensation, Material failure, Corrosion, and Faulty Installation.
The factors to determine the severity of an arc flash injury are Proximity of the worker to the hazard, Temperature, fault current, and Time for the circuit to break. The main objective of an arc flash study is to identify and analyze high-risk arc flash areas in your electrical power system with greater flexibility by simulating and evaluating various mitigation methods in arc flash study.
The National Fire Protection Association (NFPA) has developed specific approach boundaries designed to protect employees while working on or near energized equipment. These boundaries are
• Flash Protection Boundary (outer boundary)
• Limited Approach
• Restricted Approach
• Prohibited Approach (inner boundary)
The software used for the arc flash study is ETAP and DigSilent Powerfactory.
WHY ARC FLASH STUDIES?
• To determine maximum incident energy at MV and LV switchgear
• To establish the Arc flash boundary limit based on the arc fault current and fault clearing time.
• To specify the hazard/risk category
• To recommend suitable PPE for the safety of workers.
• To generate suitable danger and warning labels.
HOW DO ARC FLASH STUDIES? (METHODOLOGY)
• Collection of inputs (SLD, equipment parameters – Voltage kV rating, Power MVA rating, Impedance, System fault level, X/R ratio, protection settings).
• Check the electrode configuration of the panel based on IEEE 1584 such as VCB, VCBB, HCB, VOA, HOA
• Modeling in study software.
• Determining the bolted fault current and performing short circuit studies at each switch gear for t

Best UiPath Training in Chennai...

Searching for best ui-path training in chennai ?.here you go !!! bita offers best ui-path training course in chennai. ca...

Chennai

Call for Details
Click to add this to your watchlist
...
Powerprojectsindia

(Not Rated)

••••• •• 338

Safety Tips
  1. Meet in a public place during the daytime when other people will be around.
  2. Don't carry large sums of money with you when going to meet the seller.
  3. Never send advance payment under any circumstances.
Read all safety tips...